Project Assistent Help
Logic Module for controlling BluOS-Streaming-Devices |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IntroductionThe Gira logic module provides control of BluOS streaming devices via the Gira X1 Visualisation Server. This allows control and feedback via the Gira Smart Home app and G1 touchscreen, as well as more limited control from any KNX enabled keypad. The logic module is used to control BluOS enabled audio devices from the likes of Bluesound and NAD. In addition to operating the devices via the "Audio control with title picture" visualization object provided by the X1, it is also possible to operate them using a KNX push-button sensor. It is also possible to integrate the music control in scenes so that the devices become part of the building bus system, which is controlled by a KNX system. The following features are supported:
Equipment SetupThe BluOS Controller app (iOS or Android) must be used to initially configure the player. Using BluOS Controller, you will set up the player name, configure inputs and adjust audio settings. You also use BluOS Controller to login to streaming music services, add network music libraries, create presets etc. The logic module does not support device discovery. The BluOS devices must be configured to a static IP address, which is then entered in the parameters of the logic module. For all BluOS players, the port is set to 11000 by default. For the NAD CI580v2 4 zone player, this is different and each zone has its own port number on the same IP address. Zone 1 is Port 11000, zone 2 is Port 110010, Zone 3 is Port 11020, Zone 4 is Port 11030. |
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parameter
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inputs
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Outputs
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Notes on connecting the "Audio Control" visualization object.Use of KNX objectsIf the player is to be controlled via the KNX and the visualization of the X1 is to be used, then group address data points should be used to link the logic module with the visualization object. Parameters of the logic moduleThe following parameter settings are to be selected.
Allocation of the data points in the visualization object
Allocation of listening group addressesSince the visualization object only works with one data point per function, the status information of the following functions should be assigned via the assignment of the listening address.
Use of internal objectsIf only the visualization of the X1 is to be used, it is sufficient to use variable data points for linking the logic module with the visualization object. In this case, the same data point should be used for the following inputs and outputs of the logic module:
Notes on connecting a KNX push button sensor.Controlling the volume via the "Volume relative" input can be used with the 4-bit data type for dimming.
The push button sensor should be configured in such a way that the dimming telegram sends a stop telegram and there is no telegram repetition. It is recommended to set the increment to 3%. Every 500ms, the block sends the command to increase or decrease the volume by the set percentage to the device. The dimming switching function of the push button sensor should be linked to the Volume Up/Down input. With these specifications, a rocker of the push button sensor is given the function that the volume is changed step by step with a short press of the button and continuously with a long press of the button. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||